5
REPLACING THE ROOM STATIONS
The DMC room and door speakers use the existing wire
and speaker rough-in mounting frames or boxes. To replace
the speaker, fi rst remove the old speaker. Leave the existing
room or door station mounting rings in place.
After removing the room station verify the integrity of the
wire run. Then install the mounting plate from the DMCFR
(fi nish-out frame for room stations). Align the plate on the
wall either vertically or horizontally so that the screw holes
line up with those on the mounting ring or box. Use a level
to make sure the plate is level. There are several screw hole
locations on the mounting plate so it can attach to many
rough-in designs. Mount the plate to the wall using the
screws provided (Figure 7).
Next connect the wires to the retrofi t room station as shown
in Figure 8. Match the wire colors to the corresponding
screw locations on the DMC3 or DMC4 room stations.
Please make sure to use only DMC3 room stations in a 3-wire
installation and DMC4 room stations in a 4-wire installation.
All 6-wire, 7-wire, & 8-wire installations use the DMC1
room stations.
Please refer to Appendix A for a table of which NuTone
and M&S Systems retrofi t to the 3-wire, 4-wire, or 6-wire
(requires DMC1 master) DMC confi gurations.
Refer to the tables below for 3-wire and 4-wire mapping:
3-WIRE SYSTEM
Nutone Wire
(IW3 or equivalent)
M&S 3-Wire
DMC3-4
Equivalent
Silver outside or blue tracer
White Black
Center conductor or gray tracer
Black Red
Other outside copper wire or red tracer
Green Green
4-WIRE SYSTEM
M&S Wire
M&S or NuTone
4-conductor gray jacket wire
DMC3-4 Equivalent
White
Silver outside gray wire White
Black
Next copper outside gray wire Black
Red
Next copper outside gray wire Red
Green
Outside copper outside gray wire Green
After connecting the room station to the existing wiring.
Place the room station through the DMCFR plastic mounting
plate. Position the plate either vertically or horizontally
depending on the room station replaced. Place the room
station into the rough-in ring and align the frame with the
room station as shown in Figure 9. Use the screws provided
with the room station to screw the room station and frame
into place. The holes in the room station align with the holes
in the mounting plate. The room station keeps the plastic
frame in place on the wall.
✔ NOTE: The plastic frames are paintable. Please prime the plastic fi rst
and then apply standard room paint. The white plastic may require two
coats of paint to get full coverage. It is recommended that you paint
the frame prior to mounting it to the wall.
✔ IMPORTANT: Please label all cables at both ends. Incorrectly
connecting cables to the master, room stations or door stations could
result in system damage.
VERTICAL
MOUNTING
DMCFR PLATE
HORIZONTAL
MOUNTING
DMCFR PLATE
ATTACH A DMCFR RETROFIT MOUNTING PLATE TO THE
EXISTING ROOM STATION ROUGH-IN BOX
USE THE PLATE
HOLES THAT FIT
THE INSTALLATION
RED
WHITE
BLACK
CABLE TO
MASTER
3-WIRE
CONNECTION
GREEN
WIRE
RED
WIRE
BLACK
WIRE
WHITE TERMINAL ON
DMC4 STATIONS IS
USED IN 4-WIRE
INSTALLATIONS
DMCFR
HOUSING
BRING ROOM STATION
THROUGH THE DMCFR
HOUSING FROM THE
BACK SIDE
SCREW THE ROOM STATION
TO THE MOUNTING PLATE
WITH THE HOUSING
IN BETWEEN
Figure 7. DMCFR Mounting Plate Installation
Figure 8. Room Station Wiring (3-Wire)
Figure 9. Fitting Room Station into the DMCFR Housing